Measures to prevent fire of wires and cables:
1. Guarantee the construction quality, especially the production quality of the cable head must strictly meet the requirements of the regulations.
2. Strengthen cable operation monitoring to avoid overloaded cable operation.
3. According to the cable test, if it is found to be abnormal, it should be handled in time.
4. The cable trench should be kept dry to prevent the cable from getting wet and causing the insulation to drop, causing a short circuit.
5. Regularly clean the dust accumulated on the cable to prevent the cable from catching fire due to self-ignition of accumulated dust.
6. Strengthen regular check and maintenance of the circuit switch and protection of the cable to ensure reliable operation.
7. The cable should be kept at a sufficient distance from the heat pipe during laying, and the control cable should be no less than 0.5 meters; the power cable should not be less than 1 meter. Control cables and power cables should be divided into slots, layers and separate layouts. They cannot be placed in layers. For parts that do not meet the regulations, the cables shall be fire-retardant and heat-insulated.
8. Install a fire alarm device to detect the fire in time to prevent the cable from catching fire.
9. Take fire retardant measures. Fire-retardant measures for cables include:
(1) Wrap the cable with heat-insulated and flame-retardant materials. When the surrounding of the cable catches fire, the wrapped cable is insulated from the fire by the heat-insulated and flame-retardant material. If the cable itself catches fire, the lack of oxygen in the dressing body can cause the fire to self-extinguish and prevent the fire from spreading to the outside of the dressing.
(2) The cables shall be sealed tightly through the holes of the wall, the bottom of the plate, and the shaft with refractory material to prevent the high temperature smoke from spreading and spreading to cause the fire surface to expand when the cable catches fire.
(3) Brush fireproof coating on the surface of the cable.
(4) Wrap the area where the cable needs to be flameproof with a fireproof tape.
(5) Heat-resisting fire-retardant panels are installed between the cable layers to prevent flaring between the cable layers and to extend the fire.
(6) Set partition walls and fire doors in the cable channel to prevent the cable from igniting and expand the fire.
10. Equipped with necessary fire-fighting equipment and facilities. Overhead cable fires can be saved by commonly used fire extinguishing equipment, but automatic or remotely controlled fire extinguishing devices such as 1301 fire extinguishing devices and water spray fire extinguishing devices should be installed at cable mezzanines, shafts, trenches and tunnels.
Fire suppression of cable fires Fire suppression fires of cables When a cable fire occurs, it is necessary to promptly report an alarm, immediately identify the system and direction of the fired cable, adjust the operating mode of the fire cable as soon as possible, and cut off the power supply of the fired cable. When the cable is burned, toxic gas will be generated, so special attention must be paid to the protection against fire of the cable.
Tianjin Cable Plant Rubber Cable Factory
Brand: Kitty card
Chairman: Hao Guozheng
Sales Manager: Ren Dongxia
Tianjin Cable Plant Rubber Cable Factory (former Tianjin Third Factory)
Founded in 1972, the company is a comprehensive cable company integrating R&D, manufacturing, and sales. Over the years, he has been committed to the research, development and manufacturing of coal mine cables, high voltage cables, control cables, communication cables, rubber sheath cables and power cables.
Tianjin Cable Plant Rubber Cable Factory Main Product
Mining communication cables: MHYV, MHYVR, MHYVP, MHYVRP, MHYAV, MHYA32, MHY32, MHJYV, MHYBV, etc.
Mining control cables: MKVV, MKVVP, MKVV22, MKVV32, MKVVR, MKYJV, MKYJVP, MKYJV22, MKYJV32, MKYJVR, etc.
Mining rubber cable: MY, MYP, MYQ, MC, MCP, UGF, UGEFP, MYPTJ, MCPTJ, etc.
Mine Power Cables: MVV, MVV22, MVV32, MYJV, MYJV22, MYJV32, etc.
Computer Cables: DJYVP, DJYPVP, DJYPV, DJYVP22, DJYPVP22, JVVP, JVV, JVVRP, etc.
Communication cables: HYA, HYA22, HYA53, HYA23, HYAT, HYAT23, HYAT53, HYAT22, HYAC, HYV, HYY, etc.
Control cables: KVV, KVV22, KVV32, KVVP, KVVR, KVVRP, ZR-KVV, ZRKVV22, NH-KVV, NH-KVV22, etc.
Rubber sheath cables: YC, YCW, YZ, YZW, YQ, YQW, JHS, JHSB, CEFR, CEFRP, YHD, etc.
Power cables: VV, VV22, YJV, YJV22, NH-VV, NH-YJV, ZR-VV, ZR-YJV, etc.
Instrument cable: RS485, PVV, PVVR, PVV22, PVVP, RVV, RVVP, YVV, YVVP, SYV, etc.
Our factory can process all kinds of special cables and ZR flame retardant and NH fireproof according to customer requirements. WDZ low smoke and halogen free
With the lowest price, give you the best product, reliable product quality, let you rest assured
Связаться с нами

Author:

Ms. Amy

Электронная почта:

amy@ucoax.com

Phone/WhatsApp:

+8613913156783

Популярные продукты
Новости промышленности
You may also like
Related Categories

Письмо этому поставщику

Тема:
Электронная Почта:
сообщение:

Your message must be betwwen 20-8000 characters

Связаться с нами

Author:

Ms. Amy

Электронная почта:

amy@ucoax.com

Phone/WhatsApp:

+8613913156783

Популярные продукты
Новости промышленности

Контакты

  • Номер Телефона : 86-0512-66610280
  • Мобильный Телефон: +8613913156783
  • Электронная Почта: amy@ucoax.com
  • Адрес Компании : NO.288 HUAFENG ROAD, Suzhou, Jiangsu China

Отправить Запрос

Список сопутствующих товаров

Подписывайтесь на нас

Copyright © 2024 UCOAXВсе права защищены.
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Отправить