(1) Cable handling: The cable should be wrapped around the plate for transportation. When manpower is pushed, it should be rolled in the direction of the tightness of the cable coil or in the direction of the arrow marked on the plate. Otherwise, the cable will loosen and become twisted. It is difficult to remove the cable in the future. When transporting by car, the cable tray should be placed on the vehicle and temporarily fixed. Do not drop the disc when unloading the car. Roll it down or hang it down. Large cable trays are more difficult to roll and are best handled with a forklift. The short cable can be coiled at the specified minimum bend radius and transported after four points. The cable laying is currently artificially laid and special tools are used.

When laying the cable, place the cable tray on the cable payout rack. Place the plastic or aluminum floor pulley on the floor of the cable and place the cable on the pulley. This will not only reduce the labor intensity, but also reduce the friction of the cable on the ground and protect the cable. Not damaged. After the cables are laid in place, arrange the cables in time, arrange the cables according to the design position, and straighten the cables. Use plastic tapes or cable cards to bind and fix the cables according to the specifications. At the same time, suspend the cable cards. The cable card should have the following contents: cable number, Cable model, specifications, starting point, end point, etc. Cables should be placed at the following locations: at both ends of the cable, at the corner where the cable is changed, at the cable riser, at the middle of the cable.

(2) Cable ducting: The cable shall be protected by pipe at the following locations: the cable lead-in machine leads out of the building, tunnel, and channel; the cable passes through the floor or the wall; leads to the pole and the cable laid along the wall is off the ground A section of 2 meters in height; where the indoor cable may be mechanically damaged, the outdoor cable passes through the road and the indoor accessible cable is a section of cable 2 meters above the ground. When a cable enters a single pipe, it shall meet the following requirements: armored cable shall not penetrate into the same pipe in other cables, a cable pipe may only allow one cable to be laid, and cables laid in concrete and asbestos cement pipes shall be plastic sheathed. Cables to prevent corrosion. When laying the cable through the pipe, you should first clear the pipe. When the pipe is not long, you can directly send the cable. When there are two right-angled bends after the pipeline is lengthened, it can be penetrated into the pipe with an 8~10th iron wire, and one end is fastened on the cable. Afterwards, one end is drawn and one end is sent. In order to strengthen the lubrication, the nozzle can also be Apply talcum powder or industrial petrolatum to the cable.

(3) Directly burying the cables: When the cables are laid directly, they must be buried below the permafrost. The bottom of the trench must be a soft soil layer with no stones or other hard debris. Otherwise, it should be covered with no less than 100 mm. Sand or soft soil. The cable should also be covered with a layer of sand or soft soil not less than 100 mm. The cover is covered with concrete slabs or bricks, with a width of more than 50 mm on both sides of the cable. The slab is then backfilled with the original soil. The buried depth of buried cables shall be within the minimum distance between cables, cables and pipes, roads, and buildings when they are parallel or intersect. When the cable is laid directly, it should have a certain wave shape to prevent the uneven settlement of the ground and damage the cable. The location of the cable and joint box should be set up sign piles, should also draw the cable laying position map for transfer to the operating unit.
Связаться с нами

Author:

Ms. Amy

Электронная почта:

amy@ucoax.com

Phone/WhatsApp:

+8613913156783

Популярные продукты
Новости промышленности
You may also like
Related Categories

Письмо этому поставщику

Тема:
Электронная Почта:
сообщение:

Your message must be betwwen 20-8000 characters

Связаться с нами

Author:

Ms. Amy

Электронная почта:

amy@ucoax.com

Phone/WhatsApp:

+8613913156783

Популярные продукты
Новости промышленности

Контакты

  • Номер Телефона : 86-0512-66610280
  • Мобильный Телефон: +8613913156783
  • Электронная Почта: amy@ucoax.com
  • Адрес Компании : NO.288 HUAFENG ROAD, Suzhou, Jiangsu China

Отправить Запрос

Список сопутствующих товаров

Подписывайтесь на нас

Copyright © 2024 UCOAXВсе права защищены.
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Отправить